Post occupancy evaluation of ventilation coefficient desired for thermal comfort in educational facilities

Journal article


Mba, E.J, Okeke, F.O, Ezema, E.O, Oforji, P.I and Ozigbo, C.A 2023. Post occupancy evaluation of ventilation coefficient desired for thermal comfort in educational facilities. Journal of Human, Earth, and Future. 4 (1), pp. 88-102. https://doi.org/10.28991/HEF-2023-04-01-07
AuthorsMba, E.J, Okeke, F.O, Ezema, E.O, Oforji, P.I and Ozigbo, C.A
Abstract

In tropical regions, one sustainable measure identified to attain thermal comfort and energy savings for interior spaces is natural ventilation. However, the ventilation coefficient as a factor for effective passive ventilation required for thermal comfort in educational facilities in warm, humid climates has not been adequately investigated. This study is a post-occupancy evaluation aimed at investigating the ventilation coefficient as a parameter for effective passive ventilation efficiency for good thermal comfort in the classrooms of public primary school buildings in Enugu Metropolis, Nigeria. Among the data collection instruments are two data logging devices (thermo-anemometers-AZ 9871) used to measure air velocity, humidity levels, and temperature outside and inside the classrooms of 60 government primary school buildings in the study area. This selection was based on stratified random sampling techniques. For data analysis, the global ventilation coefficient and linear regression analysis were used. The findings demonstrate that the average natural ventilation efficiency was 80%, which is higher than the global ventilation efficiency standard of 60%. The research results further highlight that colonial classroom prototype buildings have a lower temperature value and ventilation coefficient of 83%, which in turn influenced the thermal comfort conditions of the classrooms investigated. The significance of this study is that the findings contribute to the existing knowledge base that would advance strategic policy formation towards acceleration of the uptake of sustainable and energy-efficient building designs for educational facilities in warm, humid tropical environments.

KeywordsEducational facilities; Passive ventilation; Post-occupancy evaluation; Ventilation coefficient
Year2023
JournalJournal of Human, Earth, and Future
Journal citation4 (1), pp. 88-102
PublisherItal Publication
ISSN2785 2997
Digital Object Identifier (DOI)https://doi.org/10.28991/HEF-2023-04-01-07
Official URLhttps://hefjournal.org/index.php/HEF/article/view/253
Publication dates
Print01 Mar 2023
Publication process dates
Accepted17 Feb 2023
Deposited13 Nov 2023
Publisher's version
License
File Access Level
Open
Output statusPublished
Permalink -

https://repository.canterbury.ac.uk/item/96514/post-occupancy-evaluation-of-ventilation-coefficient-desired-for-thermal-comfort-in-educational-facilities

Download files


Publisher's version
DOC-20231009-WA0007 .PDF
License: CC BY 4.0
File access level: Open

  • 34
    total views
  • 16
    total downloads
  • 0
    views this month
  • 0
    downloads this month

Export as

Related outputs

A review of corncob-based building materials as a sustainable solution for the building and construction industry
Okeke, F., Ahmed, A., Imam, A. and Hassanin, H. 2024. A review of corncob-based building materials as a sustainable solution for the building and construction industry. Hybrid Advances. 6 (100269), pp. 1-16. https://doi.org/10.1016/j.hybadv.2024.100269
Assessment of compressive strength performance of corn cob ash blended concrete: a review
Okeke, F., Ahmed, A., Imam, A. and Hassanin, H. 2024. Assessment of compressive strength performance of corn cob ash blended concrete: a review. https://doi.org/10.18552/2024/SCMT/606
Awareness of the effects of small-scale cassava mill effluent on the environment in Ika North East Local Government Area, Delta State, Nigeria.
Isimah, Matthew Ogorchukwu, Chukwurah, Gladys Ogochukwu, Okeke, Francis, Nwankwo, Cletus Famous and Nnoli, Chukwuemeka Ifedilichukwu 2023. Awareness of the effects of small-scale cassava mill effluent on the environment in Ika North East Local Government Area, Delta State, Nigeria. Environmental Monitoring and Assessment. 195 (12), p. 1431. https://doi.org/10.1007/s10661-023-12026-7
Architectural design response to population issue in sub-Saharan cities
Okeke, F.O, Ezema, E.C, Nnaemeka-Okeke, R.C, Okosun, E.A and Okeke, C.A 2023. Architectural design response to population issue in sub-Saharan cities. E3S Web of Conferences. 434 (02005). https://doi.org/10.1051/e3sconf/202343402005
Transit, walking and cycling infrastructure and sustainable development in Enugu city, Nigeria.
Andrew E. Okosun, Francis O Okeke, Ajuluchukwu E. Igwe and Emmanuel C. Ezema 2023. Transit, walking and cycling infrastructure and sustainable development in Enugu city, Nigeria. IOP Conference Series: Earth and Environmental Science. 1239 (012022), pp. 1-14. https://doi.org/10.1088/1755-1315/1239/1/012022
The effects of rhythm on building openings and fenestrations on airflow pattern in tropical low-rise residential buildings
Peter I. Oforji, Emeka J. Mba and Francis O. Okeke 2023. The effects of rhythm on building openings and fenestrations on airflow pattern in tropical low-rise residential buildings. civil engineering journal. 9 (8), pp. 2062-2084. https://doi.org/10.28991/CEJ-2023-09-08-016